Difference between revisions of "First XBee Test"
From emboxit
m (1 revision) |
|
(No difference)
|
Latest revision as of 16:51, 11 September 2015
From Robert Faludi Building Wireless Sensor Networks book chapter III Build a Better Doorbell page 57
- One node configured as Coordinator AT and the other as Router AT using X-CTU utility
- Both nodes configured from serial terminal 9600 8N1
- DH,DL is the address of the opposite node. This address is printed on the module
+++ OK ATID 2011 OK ATDH 0013A300 OK ATDL 43023E45 OK ATWR OK
- +++ changed the mode from transparent to AT commands. This lasts for 10 seconds
- PANID Address is set to 2011
- Destination Address High and Low as printed to opposite module
- Write parameters to EEPROM
- Lines 19,20 of BUTTON Arduino sketch transmits character D every 10 seconds
- Receiver Acknowledges transmitting ACK
So
- The Green-Led (RSSI)on both nodes blinks every 10 seconds
- Checking the Green Led we were able to test the RF range of the nodes
- Checking the intensity of the RSSI Green Led we have an indication of the RF link level
- The measured range is: 30 steps Indoors Line Of Sight